• NAYCY
  • NAYCY
  • NAYCY
  • NAYCY
  • NAYCY
  • NAYCY
  • NAYCY
  • NAYCY

NAYCY

NAYCY cables are used in power generation industry and switchgear, street lights, household power connections, secondary distribution networks and others. These cables are suitable for underground applications, indoor installation and cable piping and outdoor applications, open installation, and can also be laid underground and in water with mechanical protection.

$0.00
certificate:
TUV,CE
TUV,CE
CE
CE
  • NAYCY
  • NAYCY
  • NAYCY
  • NAYCY

Description

Application and description

NAYCY cables are used in power generation industry and switchgear, street lights, household power
connections, secondary distribution networks and others. These cables are suitable for underground
applications, indoor installation and cable piping and outdoor applications, open installation, and can
also be laid underground and in water with mechanical protection.
                                                                                                                                                               

Standards and certification

VDE 0276- 603, IEC 60502
                                                                                                                                                               

Cable structure

- Aluminum conductor

- VDE 0295 cl.1/cl.2(round or sector), BS 6360/IEC 60228 cl.1/cl.2

- PVC insulation DIV4 class, according to VDE0276

- Color coding follows DIN VDE 0293

- PVC wrap tape and inner sheath

- Concentric conductor: copper wire and copper strip

- PVC jacket DMV5, according to VDE 0276
                                                                                                                                                               

Technical characteristics

- Operating voltage: 600/1000 V

- Test voltage: 4000 V

- Minimum bending radius: 12 x Ø

- Operating temperature: -5º C ~ +50º C

- Fixed installation temperature: -30 º C to +70º C

- Flame retardant according to DIN VDE 0472-804 Class B /IEC 60332-1

- Insulation resistance: >20 MΩ x km
                                                                                                                                                               

Cable parameter

Core number x conductor Cross area # x mm²

Conductor type 

Concentric conductor size
mm²

Sheath thickness mm

Nominal outside diameter mm

Copper weight kg/km

Cable weightkg/km

3 x 35.0

re

35

27.9

291

230

1143

3 x 50.0

re

50

31.5

392

335

1522

3 x 70.0

se

70

33.1

567

456

1675

3 x 95.0

se

95

36.9

785

665

2247

3 x 120.0

se

120

40.0

993

849

2715

3 x 70.0

sm

35

33.1

584

236

1489

3 x 70.0

sm

70

34.1

584

413

1648

3 x 95.0

sm

50

37.7

809

296

1974

3 x 95.0

sm

95

38.7

809

580

2253

3 x 120.0

sm

70

40.2

1023

432

2381

3 x 120.0

sm

120

40.9

1023

694

2654

3 x 150.0

sm

70

44.2

1257

432

2798

3 x 150.0

sm

150

45.4

1257

804

3164

3 x 185.0

sm

95

48.6

1579

580

3498