• H07V-K
  • H07V-K
  • H07V-K
  • H07V-K

H07V-K

This cable is not suitable for laying in conduits, under and on lime, enclosed in installation pipes, and is not allowed to be installed in cable trays, channels or cable boxes. It is mainly used for internal connections of equipment, distribution boards and switches, and for lighting systems with rated voltages up to 1000 V AC or 750 V DC under protection.
$0.00
Cable parameter:
TUV,CE
TUV,CE
CE
CE
  • H07V-K
  • H07V-K

Description

Application and Description

This cable is not suitable for laying in conduits, under and on lime, enclosed in installation pipes, and is not allowed
to be installed in cable trays, channels or cable boxes. It is mainly used for internal connections of equipment,
distribution boards and switches, and for lighting systems with rated voltages up to 1000 V AC or 750 V DC
under protection.
                                                                                                                                                                                                    

Standards and certifications

HD 21.3 S3, VDE-0281 Part 3, CEI 20-20, CEI20-52,
                                                                                                                                                                                                    

Cable construction

- Stranded flexible bare copper conductor

- Complies with VDE-0295 Cl 5, IEC 60228 Cl-5

- PVC (polyvinyl chloride) TI1 insulation

- Color coding of cores complies with VDE-0293
                                                                                                                                                                                                    

Technical characteristics

- Working voltage: 450/750V

- Test voltage: 2500 V

- Dynamic bending radius: 12.5 x Ø

- Static bending radius: 12.5 x Ø

- Working temperature during application: -5º C to +70º C

- Flame retardant: IEC 60332.1

- Insulation resistance: 10 MΩ x km
                                                                                                                                                                                                    

Cable parameters:

Number of cores x conductor cross-sectional area

# x mm²

Nominal insulation thickness mm

Nominal outer diameter mm

Nominal copper weight kg/km

Nominal cable weight kg/km

1 x 1.5

0,7

3.1

14.4

20

1 x 2.5

0,8

3.6

24.0

31

1 x 4

0,8

4.3

38.0

48

1 x 6

0,8

4.9

58.0

69

1 x 10

1,0

6.4

96.0

121

1 x 16

1,0

8.1

154.0

211

1 x 25

1,2

9.8

240

303

1 x 35

1,2

11.1

336

417

1 x 50

1,4

13.1

480

539

1 x 70

1,4

15.5

672

730

1 x 95

1,6

17.2

912

900

1 x 120

1,6

19.7

1152

1135

1 x 150

1,8

21.3

1440

1410

1 x 185

2,0

23.4

1776

1845

1 x 240

2,2

27.1

2304

2270